FUSA_BMS_ASIL-D/VEC_FuSa_HeavyVehicles/commons/table_05-D6.measures

15 lines
2.8 KiB
XML
Raw Permalink Blame History

This file contains invisible Unicode characters!

This file contains invisible Unicode characters that may be processed differently from what appears below. If your use case is intentional and legitimate, you can safely ignore this warning. Use the Escape button to reveal hidden characters.

<?xml version="1.1" encoding="UTF-8"?>
<safety:MeasureCatalog xmi:version="2.0" xmlns:xmi="http://www.omg.org/XMI" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:safety="http://www.ikv.de/medini/metamodels/SafetyModel/1.0" xmi:id="_arT-sE9BEeC1A4_enB0KXA" mediniIdentifier="_arT-sE9BEeC1A4_enB0KXA" name="P-5 Table D.6 - Communication bus (serial, parallel)">
<collectionType href="http://www.ikv.de/medini/metamodels/SafetyModel/1.0#//SafetyMechanism"/>
<measures xsi:type="safety:SafetyMechanism" xmi:id="_dYdhcE9BEeC1A4_enB0KXA" mediniIdentifier="_dYdhcE9BEeC1A4_enB0KXA" id="ISO26262-5: D.2.5.1" name="One-bit hardware redundancy" maxDC="LOW" notes="-"/>
<measures xsi:type="safety:SafetyMechanism" xmi:id="_dYdhcU9BEeC1A4_enB0KXA" mediniIdentifier="_dYdhcU9BEeC1A4_enB0KXA" id="ISO26262-5: D.2.5.2" name="Multi-bit hardware redundancy" maxDC="MEDIUM" notes="-"/>
<measures xsi:type="safety:SafetyMechanism" xmi:id="_dYdhck9BEeC1A4_enB0KXA" mediniIdentifier="_dYdhck9BEeC1A4_enB0KXA" id="ISO26262-5: D.2.5.9" name="Read back of sent message" maxDC="MEDIUM" notes="-"/>
<measures xsi:type="safety:SafetyMechanism" xmi:id="_dYdhc09BEeC1A4_enB0KXA" mediniIdentifier="_dYdhc09BEeC1A4_enB0KXA" id="ISO26262-5: D.2.5.3" name="Complete hardware redundancy" maxDC="HIGH" notes="Common mode failures can reduce diagnostic coverage."/>
<measures xsi:type="safety:SafetyMechanism" xmi:id="_dYdhdE9BEeC1A4_enB0KXA" mediniIdentifier="_dYdhdE9BEeC1A4_enB0KXA" id="ISO26262-5: D.2.5.4" name="Inspection using test patterns" maxDC="HIGH" notes="-"/>
<measures xsi:type="safety:SafetyMechanism" xmi:id="_dYnScE9BEeC1A4_enB0KXA" mediniIdentifier="_dYnScE9BEeC1A4_enB0KXA" id="ISO26262-5: D.2.5.5" name="Transmission redundancy" maxDC="MEDIUM" notes="Depends on type of redundancy. Effective only against transient faults."/>
<measures xsi:type="safety:SafetyMechanism" xmi:id="_dYnScU9BEeC1A4_enB0KXA" mediniIdentifier="_dYnScU9BEeC1A4_enB0KXA" id="ISO26262-5: D.2.5.6" name="Information redundancy" maxDC="MEDIUM" notes="Depends on type of redundancy."/>
<measures xsi:type="safety:SafetyMechanism" xmi:id="_dYnSck9BEeC1A4_enB0KXA" mediniIdentifier="_dYnSck9BEeC1A4_enB0KXA" id="ISO26262-5: D.2.5.7" name="Frame counter" maxDC="MEDIUM" notes="-"/>
<measures xsi:type="safety:SafetyMechanism" xmi:id="_dYnSc09BEeC1A4_enB0KXA" mediniIdentifier="_dYnSc09BEeC1A4_enB0KXA" id="ISO26262-5: D.2.5.8" name="Timeout monitoring" maxDC="MEDIUM" notes="-"/>
<measures xsi:type="safety:SafetyMechanism" xmi:id="_dYnSdE9BEeC1A4_enB0KXA" mediniIdentifier="_dYnSdE9BEeC1A4_enB0KXA" id="ISO26262-5: D.2.5.6; D.2.5.7; D.2.5.8" name="Combination of information redundancy, frame counter and timeout monitoring" maxDC="HIGH" notes="For systems without hardware redundancy or test patterns, high coverage can be claimed for the combination of these safety mechanisms."/>
</safety:MeasureCatalog>