<?xml version="1.1" encoding="UTF-8"?>
|
|
<safety:MeasureCatalog xmi:version="2.0" xmlns:xmi="http://www.omg.org/XMI" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:safety="http://www.ikv.de/medini/metamodels/SafetyModel/1.0" xmi:id="_XHHp8DerEfCloqXVZNQXRg" mediniIdentifier="_XHHp8DerEfCloqXVZNQXRg" name="Detection Mechanisms">
|
|
<collectionType href="http://www.ikv.de/medini/metamodels/SafetyModel/1.0#//Measure"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_6B0NEIUrEe6bcr_7ut9TnA" mediniIdentifier="_6B0NEIUrEe6bcr_7ut9TnA" id="C001" name="BMS Power supply input voltage monitoring" status="NotStarted" description="The BMS shall measure input power supply (12V) to the BMS"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_yAhVUDerEfCloqXVZNQXRg" mediniIdentifier="_yAhVUDerEfCloqXVZNQXRg" id="C011" name="Secondary Current Measurement " status="NotStarted" description="Implement secondary current measurement mechanism to vaildate current data."/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_Ahg5kDesEfCloqXVZNQXRg" mediniIdentifier="_Ahg5kDesEfCloqXVZNQXRg" id="C012" name="Signal Data Digital Filtering " status="NotStarted" description="Digital Noise filtering, normally detection"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_hbfDcDewEfCloqXVZNQXRg" mediniIdentifier="_hbfDcDewEfCloqXVZNQXRg" id="C013" name="BMS part supply regulated voltage monitoring" description="Measure output of regulated power supply."/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_d40_kDexEfCloqXVZNQXRg" mediniIdentifier="_d40_kDexEfCloqXVZNQXRg" id="C014" name="FET's short detection mechanism"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_09-9QDexEfCloqXVZNQXRg" mediniIdentifier="_09-9QDexEfCloqXVZNQXRg" id="C015" name="FET's open detection Mechanism"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_7i_iYDexEfCloqXVZNQXRg" mediniIdentifier="_7i_iYDexEfCloqXVZNQXRg" id="C016" name="FET's Vds measurement "/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_yeAOoDfDEfCzjd7DVrxSEQ" mediniIdentifier="_yeAOoDfDEfCzjd7DVrxSEQ" id="C018" name="External Watchdog for MCU"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_IFIvIDfEEfCzjd7DVrxSEQ" mediniIdentifier="_IFIvIDfEEfCzjd7DVrxSEQ" id="C019" name="AFE/MCU Communication Time out"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_U5NWMDfSEfCzjd7DVrxSEQ" mediniIdentifier="_U5NWMDfSEfCzjd7DVrxSEQ" id="C020" name="3 Level Software Implementation "/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_pOGSsDn2EfCzjd7DVrxSEQ" mediniIdentifier="_pOGSsDn2EfCzjd7DVrxSEQ" id="C021" name="AFE Open Wire Detection "/>
|
|
<measures xsi:type="safety:Measure" xmi:id="__ut7wDn9EfCzjd7DVrxSEQ" mediniIdentifier="__ut7wDn9EfCzjd7DVrxSEQ" id="C024" name="Built In self Test (BIST) for detections"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_E4jG4Dn_EfCzjd7DVrxSEQ" mediniIdentifier="_E4jG4Dn_EfCzjd7DVrxSEQ" id="C025" name="Post-manufacturing Functionality Test" description="Perform FCT to check the functionality of the BMS"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_-CUkADoAEfCzjd7DVrxSEQ" mediniIdentifier="_-CUkADoAEfCzjd7DVrxSEQ" id="C026" name="HeartBeat Monitoring"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_YAGCsDoDEfCzjd7DVrxSEQ" mediniIdentifier="_YAGCsDoDEfCzjd7DVrxSEQ" id="C027" name="Monior SOC Drift" description="Mismatch between SOC change and reported current → triggers diagnostic"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_gYy5YDoLEfCzjd7DVrxSEQ" mediniIdentifier="_gYy5YDoLEfCzjd7DVrxSEQ" id="C029" name="Data Logging"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_jC_10DoLEfCzjd7DVrxSEQ" mediniIdentifier="_jC_10DoLEfCzjd7DVrxSEQ" id="C030" name="User Notification"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_RmIHkDoREfCzjd7DVrxSEQ" mediniIdentifier="_RmIHkDoREfCzjd7DVrxSEQ" id="C034" name="CAN controller error counters	" description="Increment on bit errors, ACK failures, CRC faults	"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_wtQgMDooEfCzjd7DVrxSEQ" mediniIdentifier="_wtQgMDooEfCzjd7DVrxSEQ" id="C038" name="Voltage plausiblity check "/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_HwBQMDo0EfCzjd7DVrxSEQ" mediniIdentifier="_HwBQMDo0EfCzjd7DVrxSEQ" id="C041" name="Resistance plausiblity check "/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_t-8VMDrrEfCzjd7DVrxSEQ" mediniIdentifier="_t-8VMDrrEfCzjd7DVrxSEQ" id="C042" name="Diagnostics flag on invalid input data"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_Nkz5ADuXEfCzjd7DVrxSEQ" mediniIdentifier="_Nkz5ADuXEfCzjd7DVrxSEQ" id="C043" name="Monitor voltage at the gate or control output "/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_3Z51sDuZEfCzjd7DVrxSEQ" mediniIdentifier="_3Z51sDuZEfCzjd7DVrxSEQ" id="C045" name="Gate driver self Diagnostics "/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_faddMDudEfCzjd7DVrxSEQ" mediniIdentifier="_faddMDudEfCzjd7DVrxSEQ" id="C047" name="Monitor Voltage delta across HV bus"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_5IlDAEBEEfC_8OeeB4gmCw" mediniIdentifier="_5IlDAEBEEfC_8OeeB4gmCw" id="C054" name="ADC reads constant low voltage (e.g., near 0V) → flag as short to GND."/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_6aA1sEBEEfC_8OeeB4gmCw" mediniIdentifier="_6aA1sEBEEfC_8OeeB4gmCw" id="C055" name="ADC reads constant high voltage, e.g., near Vref → flag as open"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_TuLPUEBKEfC_8OeeB4gmCw" mediniIdentifier="_TuLPUEBKEfC_8OeeB4gmCw" id="C059" name="EMI injection testing during validation stage"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_d9aDcEBKEfC_8OeeB4gmCw" mediniIdentifier="_d9aDcEBKEfC_8OeeB4gmCw" id="C060" name="Comapre threshold drift over time against spec"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_LvguwEE-EfCEYKMDCc4d7g" mediniIdentifier="_LvguwEE-EfCEYKMDCc4d7g" id="C065" name="- Alert if sensor never reaches READY/ACK state "/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_QkoqoEE-EfCEYKMDCc4d7g" mediniIdentifier="_QkoqoEE-EfCEYKMDCc4d7g" id="C066" name="- Monitor init success flags and status registers "/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_e9JBQEE-EfCEYKMDCc4d7g" mediniIdentifier="_e9JBQEE-EfCEYKMDCc4d7g" id="C068" name="Use protocol analyzer in test validation "/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_j5ip0EE-EfCEYKMDCc4d7g" mediniIdentifier="_j5ip0EE-EfCEYKMDCc4d7g" id="C069" name="Trigger fault if multiple acknowledgments occur"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="__2ApkEHfEfCEYKMDCc4d7g" mediniIdentifier="__2ApkEHfEfCEYKMDCc4d7g" id="C072" name="Rasie Flag if no response"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_GPrhYEHgEfCEYKMDCc4d7g" mediniIdentifier="_GPrhYEHgEfCEYKMDCc4d7g" id="C073" name="Alert if IR status flag is inactive post-boot
"/>
|
|
<measures xsi:type="safety:Measure" xmi:id="_qmb9UFiwEfCY24YlMe8F_Q" mediniIdentifier="_qmb9UFiwEfCY24YlMe8F_Q" id="C079" name="[FL] Monitor Input Supply Voltage"/>
|
|
</safety:MeasureCatalog>
|