Fusa_Medini/FuSa_BMS_2W/commons/_4uIXoIUrEe6bcr_7ut9TnA.mea...

44 lines
8.1 KiB
XML

<?xml version="1.1" encoding="UTF-8"?>
<safety:MeasureCatalog xmi:version="2.0" xmlns:xmi="http://www.omg.org/XMI" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:safety="http://www.ikv.de/medini/metamodels/SafetyModel/1.0" xmi:id="_4uIXoIUrEe6bcr_7ut9TnA" mediniIdentifier="_4uIXoIUrEe6bcr_7ut9TnA" name="Prevention Mechanisms">
<collectionType href="http://www.ikv.de/medini/metamodels/SafetyModel/1.0#//Measure"/>
<measures xsi:type="safety:Measure" xmi:id="_n5F94DehEfCloqXVZNQXRg" mediniIdentifier="_n5F94DehEfCloqXVZNQXRg" id="C006" name="BMS input power connector for 12V/GND shall be polarised and wire shall be color coded" description="It should not be possible for the input power connector to the BMS (12V) be connected in reverse polarity."/>
<measures xsi:type="safety:Measure" xmi:id="_yuUbADehEfCloqXVZNQXRg" mediniIdentifier="_yuUbADehEfCloqXVZNQXRg" id="C007" name="Color coding of power cables to the input power connector " description="Power cables to the input power connector (12V) shall be color coded;&#xD;&#xA;+12V - Red&#xD;&#xA;GND - Black"/>
<measures xsi:type="safety:Measure" xmi:id="_Pu48UDekEfCloqXVZNQXRg" mediniIdentifier="_Pu48UDekEfCloqXVZNQXRg" id="C008" name="Positive locking bms input power connector (12V)" description="The selected input power connector for BMS power supply (12V) shall be automotive grade, positive latch locking with clicking mechanism, and sealed"/>
<measures xsi:type="safety:Measure" xmi:id="_JJijgDelEfCloqXVZNQXRg" mediniIdentifier="_JJijgDelEfCloqXVZNQXRg" id="C009" name="Shunt measurement filtering" description="Implement shunt measurement hardware filters"/>
<measures xsi:type="safety:Measure" xmi:id="_JYBSIDeqEfCloqXVZNQXRg" mediniIdentifier="_JYBSIDeqEfCloqXVZNQXRg" id="C010" name="Shunt Temperature Measurement Filtering "/>
<measures xsi:type="safety:Measure" xmi:id="_qs24cDfBEfCzjd7DVrxSEQ" mediniIdentifier="_qs24cDfBEfCzjd7DVrxSEQ" id="C017" name="Sensor Calibration for accurate readings"/>
<measures xsi:type="safety:Measure" xmi:id="_XREoQDn9EfCzjd7DVrxSEQ" mediniIdentifier="_XREoQDn9EfCzjd7DVrxSEQ" id="C022" name="Use Automotive [XX&#x5d; grade wires with proper routing"/>
<measures xsi:type="safety:Measure" xmi:id="_sL5cYDn9EfCzjd7DVrxSEQ" mediniIdentifier="_sL5cYDn9EfCzjd7DVrxSEQ" id="C023" name="Use Guard traces and robust tracing sizing according to DRC in PCB layout" description="Follow Design Rule Checks (DRC) in PCB Layout "/>
<measures xsi:type="safety:Measure" xmi:id="_SQIu4DoGEfCzjd7DVrxSEQ" mediniIdentifier="_SQIu4DoGEfCzjd7DVrxSEQ" id="C028" name="CRC Check for DATA accuracy"/>
<measures xsi:type="safety:Measure" xmi:id="_m-0LIDoLEfCzjd7DVrxSEQ" mediniIdentifier="_m-0LIDoLEfCzjd7DVrxSEQ" id="C031" name="Watchdog timers " description="Monitor expected message intervals (e.g., heartbeat from charger) to detect loss of communication early&#xD;&#xA;"/>
<measures xsi:type="safety:Measure" xmi:id="_vV9cQDoLEfCzjd7DVrxSEQ" mediniIdentifier="_vV9cQDoLEfCzjd7DVrxSEQ" id="C032" name="Robust communication hardware" description="Use AEC-Q qualified transceivers, EMI-protected interfaces, and redundant wiring where applicable&#xD;&#xA;"/>
<measures xsi:type="safety:Measure" xmi:id="_La4tUDoREfCzjd7DVrxSEQ" mediniIdentifier="_La4tUDoREfCzjd7DVrxSEQ" id="C033" name="Use of Shielded twisted pair of cables (EMI)" description="Reduces EMI and differential noise on CAN-H/CAN-L&#xD;&#xA;"/>
<measures xsi:type="safety:Measure" xmi:id="_uQNz0DoZEfCzjd7DVrxSEQ" mediniIdentifier="_uQNz0DoZEfCzjd7DVrxSEQ" id="C036" name="Use contactors rated for switching under load"/>
<measures xsi:type="safety:Measure" xmi:id="_kgalUDonEfCzjd7DVrxSEQ" mediniIdentifier="_kgalUDonEfCzjd7DVrxSEQ" id="C037" name="Use Automotive [XX&#x5d; grade components"/>
<measures xsi:type="safety:Measure" xmi:id="_KqHq0DopEfCzjd7DVrxSEQ" mediniIdentifier="_KqHq0DopEfCzjd7DVrxSEQ" id="C039" name="Voltage sensor calibration"/>
<measures xsi:type="safety:Measure" xmi:id="_zL5E0DozEfCzjd7DVrxSEQ" mediniIdentifier="_zL5E0DozEfCzjd7DVrxSEQ" id="C040" name="Resistance Measurement Filtering "/>
<measures xsi:type="safety:Measure" xmi:id="__9DX8DuYEfCzjd7DVrxSEQ" mediniIdentifier="__9DX8DuYEfCzjd7DVrxSEQ" id="C044" name="Perform HIL testing "/>
<measures xsi:type="safety:Measure" xmi:id="_MiiU8DudEfCzjd7DVrxSEQ" mediniIdentifier="_MiiU8DudEfCzjd7DVrxSEQ" id="C046" name="Mechanism to ensure precharge done before HV close"/>
<measures xsi:type="safety:Measure" xmi:id="_-8Y9cDueEfCzjd7DVrxSEQ" mediniIdentifier="_-8Y9cDueEfCzjd7DVrxSEQ" id="C048" name="Enable digital filtering on GPIO pins"/>
<measures xsi:type="safety:Measure" xmi:id="_NVR_IEBAEfC_8OeeB4gmCw" mediniIdentifier="_NVR_IEBAEfC_8OeeB4gmCw" id="C049" name="Voltage Monitoring "/>
<measures xsi:type="safety:Measure" xmi:id="_wUmMQEBBEfC_8OeeB4gmCw" mediniIdentifier="_wUmMQEBBEfC_8OeeB4gmCw" id="C050" name="Perform thermal transient simulation simulation for high load cases "/>
<measures xsi:type="safety:Measure" xmi:id="_9lrn0EBBEfC_8OeeB4gmCw" mediniIdentifier="_9lrn0EBBEfC_8OeeB4gmCw" id="C051" name="Follow lyaout guidelines like large copper pour, thermal vias nad use power dissipation calculators "/>
<measures xsi:type="safety:Measure" xmi:id="_p5j7IEBEEfC_8OeeB4gmCw" mediniIdentifier="_p5j7IEBEEfC_8OeeB4gmCw" id="C052" name="Use Diagnostics capable transciever"/>
<measures xsi:type="safety:Measure" xmi:id="_rWM4QEBEEfC_8OeeB4gmCw" mediniIdentifier="_rWM4QEBEEfC_8OeeB4gmCw" id="C053" name="Use series resistor or current-limiting resistor to prevent supply damage. "/>
<measures xsi:type="safety:Measure" xmi:id="_FQ44oEBFEfC_8OeeB4gmCw" mediniIdentifier="_FQ44oEBFEfC_8OeeB4gmCw" id="C056" name="Thermistors placement far from HV switching nodes"/>
<measures xsi:type="safety:Measure" xmi:id="_LIjPkEBFEfC_8OeeB4gmCw" mediniIdentifier="_LIjPkEBFEfC_8OeeB4gmCw" id="C057" name="PCB Cleanliness, use conformal coating"/>
<measures xsi:type="safety:Measure" xmi:id="_L6QAAEBKEfC_8OeeB4gmCw" mediniIdentifier="_L6QAAEBKEfC_8OeeB4gmCw" id="C058" name="Us eof shieled gate lines, use twisted pair or controlled impedance routing "/>
<measures xsi:type="safety:Measure" xmi:id="_NedsUEBsEfC_8OeeB4gmCw" mediniIdentifier="_NedsUEBsEfC_8OeeB4gmCw" id="C061" name="Time based gating and min-delay enforcement "/>
<measures xsi:type="safety:Measure" xmi:id="_Qza18EBsEfC_8OeeB4gmCw" mediniIdentifier="_Qza18EBsEfC_8OeeB4gmCw" id="C062" name="Use debounce GPIO signals "/>
<measures xsi:type="safety:Measure" xmi:id="_WIiMkECEEfC_8OeeB4gmCw" mediniIdentifier="_WIiMkECEEfC_8OeeB4gmCw" id="C063" name="Add NTC on Mosfets"/>
<measures xsi:type="safety:Measure" xmi:id="_DaUlcEE-EfCEYKMDCc4d7g" mediniIdentifier="_DaUlcEE-EfCEYKMDCc4d7g" id="C064" name="Add handshake or init conirmation sequence "/>
<measures xsi:type="safety:Measure" xmi:id="_YU6wEEE-EfCEYKMDCc4d7g" mediniIdentifier="_YU6wEEE-EfCEYKMDCc4d7g" id="C067" name="Design seperate CS lines for SPI, addreess management for I2C"/>
<measures xsi:type="safety:Measure" xmi:id="_AxRXMEFMEfCEYKMDCc4d7g" mediniIdentifier="_AxRXMEFMEfCEYKMDCc4d7g" id="C070" name="Use synchronous sampling clocks "/>
<measures xsi:type="safety:Measure" xmi:id="_97vVQEHfEfCEYKMDCc4d7g" mediniIdentifier="_97vVQEHfEfCEYKMDCc4d7g" id="C071" name="Verify IR module is enabled in startup logic&#x9;"/>
<measures xsi:type="safety:Measure" xmi:id="_VJnpwEHjEfCEYKMDCc4d7g" mediniIdentifier="_VJnpwEHjEfCEYKMDCc4d7g" id="C074" name="Verify Chassis connection with continuity check "/>
<measures xsi:type="safety:Measure" xmi:id="_t3tL8EIWEfCEYKMDCc4d7g" mediniIdentifier="_t3tL8EIWEfCEYKMDCc4d7g" id="C075" name="Use pull-up/ pull-down bias with open line detection"/>
<measures xsi:type="safety:Measure" xmi:id="_0zmVIEIYEfCEYKMDCc4d7g" mediniIdentifier="_0zmVIEIYEfCEYKMDCc4d7g" id="C076" name="Optimze signal schdueling, reduce chatter"/>
<measures xsi:type="safety:Measure" xmi:id="_5eglEEIYEfCEYKMDCc4d7g" mediniIdentifier="_5eglEEIYEfCEYKMDCc4d7g" id="C077" name="Use termincal resistance at both ends "/>
<measures xsi:type="safety:Measure" xmi:id="_mMz1cEIZEfCEYKMDCc4d7g" mediniIdentifier="_mMz1cEIZEfCEYKMDCc4d7g" id="C078" name="use galvanic Isolation"/>
</safety:MeasureCatalog>