<safety:MeasureCatalog xmi:version="2.0" xmlns:xmi="http://www.omg.org/XMI" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:safety="http://www.ikv.de/medini/metamodels/SafetyModel/1.0" xmi:id="_nyoFIE8_EeCE3d5AJuslQw" mediniIdentifier="_nyoFIE8_EeCE3d5AJuslQw" name="P-5 Table D.2 - Systems">
<collectionType href="http://www.ikv.de/medini/metamodels/SafetyModel/1.0#//SafetyMechanism"/>
<measures xsi:type="safety:SafetyMechanism" xmi:id="_xrXPYk9AEeC1A4_enB0KXA" mediniIdentifier="_xrXPYk9AEeC1A4_enB0KXA" id="ISO26262-5: D.2.1.1" name="Failure detection by on-line monitoring" maxDC="LOW" notes="Depends on diagnostic coverage of failure detection" user_activated_="YES"/>
<measures xsi:type="safety:SafetyMechanism" xmi:id="_xrhAYE9AEeC1A4_enB0KXA" mediniIdentifier="_xrhAYE9AEeC1A4_enB0KXA" id="ISO26262-5: D.2.1.2" name="Comparator" maxDC="HIGH" notes="Depends on the quality of the comparison" user_activated_="YES"/>
<measures xsi:type="safety:SafetyMechanism" xmi:id="_xrhAYU9AEeC1A4_enB0KXA" mediniIdentifier="_xrhAYU9AEeC1A4_enB0KXA" id="ISO26262-5: D.2.1.3" name="Majority voter" maxDC="HIGH" notes="Depends on the quality of the voting" user_activated_="YES"/>
<measures xsi:type="safety:SafetyMechanism" xmi:id="_xrhAYk9AEeC1A4_enB0KXA" mediniIdentifier="_xrhAYk9AEeC1A4_enB0KXA" id="ISO26262-5: D.2.2.1" name="Dynamic principles" maxDC="MEDIUM" notes="Depends on diagnostic coverage of failure detection" user_activated_="YES"/>
<measures xsi:type="safety:SafetyMechanism" xmi:id="_xrhAY09AEeC1A4_enB0KXA" mediniIdentifier="_xrhAY09AEeC1A4_enB0KXA" id="ISO26262-5: D.2.2.2" name="Analogue signal monitoring in preference to digital on/off states " maxDC="LOW" notes="-" user_activated_="YES"/>
<measures xsi:type="safety:SafetyMechanism" xmi:id="_xrhAZE9AEeC1A4_enB0KXA" mediniIdentifier="_xrhAZE9AEeC1A4_enB0KXA" id="ISO26262-5: D.2.3.3" name="Self-test by software cross exchange between two independent units" maxDC="MEDIUM" notes="Depends of the quality of the self test" user_activated_="YES"/>
</safety:MeasureCatalog>