Fusa_Medini/FUSA_BMS_ASIL_C/failures/_cbbEsBTuEe-dDYDkEPKO1w.fai...

47 lines
3.7 KiB
XML

<?xml version="1.1" encoding="UTF-8"?>
<safety:FailureCollection xmi:version="2.0" xmlns:xmi="http://www.omg.org/XMI" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:safety="http://www.ikv.de/medini/metamodels/SafetyModel/1.0" xmi:id="_cbbEsBTuEe-dDYDkEPKO1w" mediniIdentifier="_cbbEsBTuEe-dDYDkEPKO1w" name="Failure modes - FETs">
<collectionType href="http://www.ikv.de/medini/metamodels/SafetyModel/1.0#//FailureMode"/>
<failures xsi:type="safety:FailureMode" xmi:id="_c1LogBTuEe-dDYDkEPKO1w" mediniIdentifier="_c1LogBTuEe-dDYDkEPKO1w" id="FM437" name="Failed open"/>
<failures xsi:type="safety:FailureMode" xmi:id="_eFGYQBTuEe-dDYDkEPKO1w" mediniIdentifier="_eFGYQBTuEe-dDYDkEPKO1w" id="FM438" name="Failed short"/>
<failures xsi:type="safety:FailureMode" xmi:id="_eyBIoBTuEe-dDYDkEPKO1w" mediniIdentifier="_eyBIoBTuEe-dDYDkEPKO1w" id="FM439" name="Over-heating"/>
<failures xsi:type="safety:FailureMode" xmi:id="_3_DaQGLiEfCvysWrHpgykQ" mediniIdentifier="_3_DaQGLiEfCvysWrHpgykQ" id="FM1387" name="Balancing Mosfets Open/Short">
<effectRelations xmi:id="_6zB9wWLiEfCvysWrHpgykQ">
<effect xsi:type="safety:FailureMode" href="../sysml/_j1o7QIUqEe6bcr_7ut9TnA.sysml#_G_8_EF4sEfCZKp8u5J2grA"/>
</effectRelations>
</failures>
<failures xsi:type="safety:FailureMode" xmi:id="_uLJ6cGLmEfCvysWrHpgykQ" mediniIdentifier="_uLJ6cGLmEfCvysWrHpgykQ" id="FM1397" name="Thermal Damage">
<effectRelations xmi:id="_4zFicGLmEfCvysWrHpgykQ">
<effect xsi:type="safety:FailureMode" href="../sysml/_j1o7QIUqEe6bcr_7ut9TnA.sysml#_utk-UF5BEfCZKp8u5J2grA"/>
</effectRelations>
<effectRelations xmi:id="_8DduEGLmEfCvysWrHpgykQ">
<effect xsi:type="safety:FailureMode" href="../sysml/_j1o7QIUqEe6bcr_7ut9TnA.sysml#_vIbHQF5BEfCZKp8u5J2grA"/>
</effectRelations>
<effectRelations xmi:id="_cJ2LoGk9EfC0mMXW96r_VA">
<effect xsi:type="safety:FailureMode" href="../sysml/_j1o7QIUqEe6bcr_7ut9TnA.sysml#_mtXohl4rEfCZKp8u5J2grA"/>
</effectRelations>
</failures>
<failures xsi:type="safety:FailureMode" xmi:id="_vj2LsGLmEfCvysWrHpgykQ" mediniIdentifier="_vj2LsGLmEfCvysWrHpgykQ" id="FM1398" name="Communication error">
<effectRelations xmi:id="_4zFicWLmEfCvysWrHpgykQ">
<effect xsi:type="safety:FailureMode" href="../sysml/_j1o7QIUqEe6bcr_7ut9TnA.sysml#_utk-UF5BEfCZKp8u5J2grA"/>
</effectRelations>
<effectRelations xmi:id="_71kcAGLmEfCvysWrHpgykQ">
<effect xsi:type="safety:FailureMode" href="../sysml/_j1o7QIUqEe6bcr_7ut9TnA.sysml#_vIbHQF5BEfCZKp8u5J2grA"/>
</effectRelations>
</failures>
<failures xsi:type="safety:FailureMode" xmi:id="_-3tXUGLmEfCvysWrHpgykQ" mediniIdentifier="_-3tXUGLmEfCvysWrHpgykQ" id="FM1399" name="Gate driver output signal missing ">
<effectRelations xmi:id="_Cg2oQGLnEfCvysWrHpgykQ">
<effect xsi:type="safety:FailureMode" href="../sysml/_j1o7QIUqEe6bcr_7ut9TnA.sysml#_vIbHQF5BEfCZKp8u5J2grA"/>
</effectRelations>
</failures>
<failures xsi:type="safety:FailureMode" xmi:id="_WUSGcGk9EfC0mMXW96r_VA" mediniIdentifier="_WUSGcGk9EfC0mMXW96r_VA" id="FM1788" name="Over-Voltage on Vds/ High voltage transients ">
<effectRelations xmi:id="_cJ2ysGk9EfC0mMXW96r_VA">
<effect xsi:type="safety:FailureMode" href="../sysml/_j1o7QIUqEe6bcr_7ut9TnA.sysml#_mtXohl4rEfCZKp8u5J2grA"/>
</effectRelations>
</failures>
<failures xsi:type="safety:FailureMode" xmi:id="_YupaoGk-EfC0mMXW96r_VA" mediniIdentifier="_YupaoGk-EfC0mMXW96r_VA" id="FM1789" name="Solder Bridge/Conductive contamination">
<effectRelations xmi:id="_cQphwGk-EfC0mMXW96r_VA">
<effect xsi:type="safety:FailureMode" href="../sysml/_j1o7QIUqEe6bcr_7ut9TnA.sysml#_mtXohl4rEfCZKp8u5J2grA"/>
</effectRelations>
</failures>
</safety:FailureCollection>