fix: Disable retry for CAN-transmitted data in FOTA.
- Resolved issue where FOTA retry count reduced unexpectedly (from 50 to 44-35). - Root cause: CAN transmission failures triggered delayed retries. - Solution: Disabled retry mechanism for CAN-transmitted data to maintain expected retry count.stable
parent
071788de56
commit
60c93c2210
|
|
@ -37,7 +37,7 @@ static DL_MCAN_InitParams __gprv_xInitParams= {
|
|||
.txpEnable = false,
|
||||
.efbi = false,
|
||||
.pxhddisable = false,
|
||||
.darEnable = false,
|
||||
.darEnable = true,
|
||||
.wkupReqEnable = true,
|
||||
.autoWkupEnable = true,
|
||||
.emulationEnable = true,
|
||||
|
|
@ -498,7 +498,6 @@ IVEC_McalCommonErr_e xMCAL_MCANDeInit(IVEC_McalCanHandle_s* pxCanHandle)
|
|||
|
||||
/* Wait for power down to complete */
|
||||
delay_cycles(16);
|
||||
|
||||
return commonMCAL_SUCCESS;
|
||||
}
|
||||
|
||||
|
|
|
|||
|
|
@ -26,7 +26,7 @@ IVEC_EcuCANHandle_s g_xCanHandle;
|
|||
#define rteCONFIG_BASIL_u8 2
|
||||
|
||||
// UART Configuration
|
||||
#define rteUART_PIN_SELECTION_u8 rteCONFIG_BASIL_BATTERY_SMART_u8
|
||||
#define rteUART_PIN_SELECTION_u8 rteCONFIG_BASIL_u8
|
||||
|
||||
uint8_t g_pu8UartBuffer[ecuUART_MAX_PACKET_LENGTH_u8] = {0};
|
||||
volatile uint32_t g_u32CanId = 0x1FFFFFFF;
|
||||
|
|
|
|||
Loading…