6.5 KiB
Mandatory symbol parameters (.SchLib)
Vecmocon's Altium SOP (§5) requires every schematic-library symbol to carry a fixed set of
parameters in its component properties (the panel shown in Altium: Properties → Parameters).
This file defines that set, where each value comes from, and how the skill stamps them onto the
.SchLib symbol.
How the parameters get in: the skill writes them directly into the .SchLib in pure Python
via scripts/schlib_write.py — it rebuilds the OLE compound file around the enlarged component
Data stream while preserving every other byte (all other streams, the directory tree, the
Altium CLSIDs). It also removes the Ultra-Librarian default params Manufacturer_Name and
Manufacturer_Part_Number, which just duplicate the SOP Manufacturer / Manufacturer Part.
The output is a ready .SchLib. Because this writes Altium's own format from outside Altium, the
script self-checks that the result re-opens as a valid OLE with the params present — but always
open the result in Altium once to confirm it loads before relying on it. (An older path,
scripts/altium_params.py, instead emits an Altium DXP script to stamp the same parameters from
inside Altium; keep it as a fallback if a particular file doesn't round-trip.)
The parameter set
Use these exact Altium parameter names (they must match the symbol, per the SOP screenshot).
The Comment field is set to the MPN (SOP §4), and the Description field is the strict
string from references/description_format.md.
| Parameter | Source | Notes |
|---|---|---|
Value |
datasheet | the component value only (no package), in shorthand — e.g. 1u, 12p, 100n, 10k |
Manufacturer Part |
datasheet | the MPN; also the Comment field |
Manufacturer |
datasheet | manufacturer name as printed, e.g. YAGEO |
Manufacturer Part 2 |
leave blank (for now) | second-source MPN — left empty by default; see optional note below |
Manufacturer 2 |
leave blank (for now) | second-source manufacturer — left empty by default |
Process |
derived | assembly process from package: SMD → Reflow, through-hole → Wave/Manual; confirm |
Vecmocon Part Code |
engineer | internal code (e.g. VECESC2421) — not on the datasheet; ask |
Operating Temperature |
datasheet | full range, e.g. -55 °C to +125 °C |
Tolerance |
datasheet | e.g. 1% (or ±1%) |
Datasheet |
datasheet | source URL or document reference (SOP marks this optional) |
ROHS |
datasheet | RoHS compliance, Yes/No |
Read the datasheet-sourced values from the actual datasheet — don't echo whatever text was
handed to you. Open the PDF, find each real value (Value, Manufacturer Part,
Manufacturer, Operating Temperature, Tolerance, Datasheet, ROHS, and Process by
inference from the package), and fill them verified. An honest blank beats a guess — the SOP
hides blank parameters, so a gap just stays empty until someone fills it. Only one field is
purely internal and must come from the engineer: Vecmocon Part Code — ask for it.
The second-source pair (Manufacturer 2 / Manufacturer Part 2) is left blank for now —
don't populate it by default. It simply stays hidden in Altium until someone fills it later.
Optional: second-source cross-reference (currently off)
House preference right now is to leave Manufacturer 2 / Manufacturer Part 2 blank, so do
not do this unless the engineer explicitly asks you to find a second source. It's documented
here so it can be switched on later without redesigning anything.
If asked to find a second source, it is an equivalent part from a different manufacturer that could drop into the design unchanged:
- Pull the original's form-fit-function specs from the datasheet — capacitance, voltage, tolerance, dielectric/temp class, package (for a cap); resistance, power, tolerance, package (for a resistor); and so on per type.
- Search for an equivalent from a different manufacturer (distributor/parametric
cross-reference, "equivalent to
<MPN>", or another reputable maker's matching series). It must match every form-fit-function spec and be at least as good on tolerance / voltage / temperature — never worse. - Fill
Manufacturer 2= its maker,Manufacturer Part 2= its exact MPN.
Two hard rules if this is ever used: never invent an MPN (only a part number you verified exists; else leave blank), and always flag the chosen second source for the engineer to confirm with the specs you compared.
Building the parameter set
Collect the values into a params.json (same spirit as part.json). component is the
symbol's Library Ref (from altium_refs.py); omit it to apply to every component in the lib.
{
"component": "CC0402FRNPO9BN120",
"comment": "CC0402FRNPO9BN120",
"parameters": {
"Value": "12pF_0402",
"Manufacturer Part": "CC0402FRNPO9BN120",
"Manufacturer": "YAGEO",
"Manufacturer Part 2": "0402N120F500CT",
"Manufacturer 2": "Walsin Tech Corp",
"Process": "Reflow",
"Vecmocon Part Code": "VECESC2421",
"Operating Temperature": "-55 °C to +125 °C",
"Tolerance": "1%",
"Datasheet": "https://www.lcsc.com/datasheet/C326662.pdf",
"ROHS": "Yes"
}
}
Writing them into the symbol
Write the parameters straight into the .SchLib, producing a new file:
python scripts/schlib_write.py --schlib <in>.SchLib --params params.json --out <out>.SchLib
params.json may carry a "remove" list (defaults to ["Manufacturer_Name", "Manufacturer_Part_Number"]); those Ultra-Librarian defaults are stripped and the SOP params
added. The script targets the component named in "component" (its Library Ref / storage name),
or every component if omitted, and self-checks the output re-opens as a valid OLE. Deliver the
resulting .SchLib, and have the engineer open it in Altium once to confirm it loads, then Save
to Server with a revision note per the SOP.
Scope note: the direct writer keeps a component's Data under Altium's 4096-byte mini-stream
threshold in the common case; a very large parameter set (or an extremely long datasheet URL)
can push it past that, at which point fall back to the altium_params.py DXP-script path.
Fallback (apply from inside Altium):
python scripts/altium_params.py script --params params.json --out apply_params.pas
Then in Altium: open the .SchLib, DXP → Run Script… → ApplyParameters, review, Save to
Server.